Gas utility software for a municipal system should connect leak response, crews and compliance records to the fire department and 911 center that respond with them. Elarchon puts gas work orders, assets and incident records on the same operational record as fire and emergency management, supporting the emergency plan, liaison and recordkeeping that 49 CFR Part 192 requires of operators.
Municipal gas systems
Some cities and utility districts own and operate natural gas distribution systems. As operators, they are subject to the federal minimum safety standards in 49 CFR Part 192, administered by PHMSA and, for intrastate systems, typically enforced through a state pipeline safety program. Incident reporting rules are in 49 CFR Part 191. The data notes for Elarchon's natural gas applications describe the scope: leaks, compliance and crews.
Leak response, with the fire department
Gas odor and leak calls usually reach 911 first, and the fire department is often first on scene. Section 192.615 requires each operator's written emergency procedures to provide, among other things, for:
- receiving, identifying and classifying notices of events that require immediate response;
- maintaining communication with the 911 center, fire, police and other public officials, and informing them of the operator's ability to respond;
- prompt response to gas detected inside or near a building, fires or explosions involving a pipeline facility, and natural disasters;
- actions to protect people first, then property, including emergency shutdown, valve shut-off or pressure reduction;
- notifying the 911 center and other officials of emergencies.
When the gas utility and the fire department work on one record, the fire incident, the utility's response and the repair work order are linked. Fire incident records are built natively on NERIS version 1.5; see fire and rescue.
Incident notice
Under 49 CFR 191.5, an operator must notify the National Response Center at the earliest practicable moment after discovery, and no later than one hour after confirmed discovery, of each incident meeting the definition in 49 CFR 191.3, then revise or confirm that notice within 48 hours. A shared record gives the operator the time line, location and facts the notice requires from what responders and crews already recorded.
Crews, assets and compliance records
| Need | In Elarchon |
|---|---|
| Leak and repair work | Work Orders with crews, hours, equipment and materials. See work orders. |
| Assets | GIS Asset Registry for mains, services and valves with their history. |
| Readings | Sensors & Telemetry joins readings to the record. See sensors and telemetry. |
| Training | Credentials & Training for operator qualification and training records. |
| Public awareness | Public Alerts for notices to residents, alongside the operator's public awareness program under 49 CFR 192.616. |
| Reporting | Report Builder for compliance and management reports. |
Natural disasters and gas systems
Section 192.615 lists natural disasters among the emergencies an operator's plan must address. Floods, earthquakes and storms can damage mains and services across a wide area at the same time the fire department, public works and emergency management are stretched. When gas crews record their work on the same record as the rest of the response, the EOC can see which areas have been made safe and where crews are working, and the utility's labor, equipment and materials are documented against the incident for any later cost recovery. See emergency management.
Questions to ask any vendor
- How are leak calls from 911 and the fire department linked to the utility's response and repair?
- Can the system produce the facts needed for an incident notice quickly?
- How are crew qualifications and training recorded?
- How does it connect to existing GIS and SCADA?
Elarchon supports an operator's records; compliance with Part 192 remains the operator's responsibility under its state pipeline safety program.
Questions
Which federal rules apply to municipal gas distribution systems?
Gas pipeline safety rules in 49 CFR Part 192, administered by PHMSA and, for intrastate systems, usually by a state pipeline safety program. Incident reporting requirements are in 49 CFR Part 191.
What must a gas operator's emergency plan include?
Under 49 CFR 192.615, written procedures for receiving and classifying emergency notices, communicating with 911 centers, fire, police and other officials, responding to gas detected in or near a building, fires, explosions and natural disasters, making safe hazards and notifying public officials, among other elements.
How quickly must a gas incident be reported?
Under 49 CFR 191.5, an operator must give notice to the National Response Center at the earliest practicable moment following discovery, and no later than one hour after confirmed discovery, of each incident as defined in 49 CFR 191.3.
How does the fire department fit in?
Fire departments are often first on scene for gas odor and leak calls. Section 192.615 requires operators to maintain liaison with fire, police and other public officials. When the gas utility and fire department share one record, the call, the response and the utility's work are linked.
Does Elarchon replace a gas utility's GIS or SCADA?
No. Elarchon's Sensors & Telemetry joins readings to the operational record and the GIS Asset Registry holds assets and history; existing SCADA and GIS systems remain the systems of control.
What does an operator's public awareness program cover?
Under 49 CFR 192.616, operators must develop and implement a written continuing public education program covering, among other audiences, the public, emergency officials and local public officials, so they can recognize and respond to a gas pipeline emergency.