ELARCHON Request a briefing

Standards guide

NFPA 1710 vs 1720: response times, staffing and which one applies

NFPA 1710 sets deployment and response benchmarks for career fire departments. NFPA 1720 does the same for volunteer and mostly volunteer departments. This guide explains the difference, the benchmarks each one uses, and how departments measure themselves against them.

Updated November 21, 2026 · Reviewed against 7 official and primary sources · Editorial standards

NFPA 1710 vs 1720 comes down to who staffs the department. NFPA 1710 applies to career fire departments and sets 90th-percentile benchmarks, such as 60 to 80 seconds of turnout and 240 seconds of travel for the first engine. NFPA 1720 applies to volunteer and mostly volunteer departments and sets staffing and response time objectives by demand zone, from urban to rural.

Two standards, two kinds of department

The National Fire Protection Association publishes both standards. They answer the same question, how quickly and with how many people a department should arrive, for different organizations.

Neither is law on its own. A standard becomes binding when a state, local ordinance or labor agreement adopts it. In practice, chiefs use them to set targets in a standard of cover, justify station locations and staffing, and report performance to councils.

NFPA 1710 response times

NFPA 1710 measures time in segments and sets an objective for each, met at least 90 percent of the time. The figures below are from NFPA's fact sheet for the 2020 edition.

SegmentBenchmarkCompliance
Turnout time, EMS60 seconds90 percent
Turnout time, fire and special operations80 seconds90 percent
Travel time, first-arriving engine240 seconds (4 minutes)90 percent
Travel time, initial full alarm assignment (low and medium hazard)480 seconds (8 minutes)90 percent

Turnout starts when units are notified and ends when they begin moving. Travel starts when they begin moving and ends when they arrive. Alarm handling at the communications center is measured separately. The DC Fire and EMS Department publishes a practical example of reporting each segment this way.

NFPA 1710 staffing

NFPA 1710 also sets minimum staffing for engine and truck companies and for the initial full alarm assignment, scaled to the hazard of the occupancy. Exact numbers depend on the edition and the hazard category; read them from the current edition of the standard, which NFPA makes available for free viewing on its site.

NFPA 1720 demand zones

NFPA 1720 does not use one national clock. It asks the authority having jurisdiction to assign each area a demand zone based on population density, then sets a minimum number of responding members, a response time and a percentage of compliance for each zone. Response time in NFPA 1720 combines turnout and travel.

Demand zonePopulation densityMinimum staff to respondResponse timeCompliance
UrbanMore than 1,000 people per square mile159 minutes90 percent
Suburban500 to 1,000 people per square mile1010 minutes80 percent
RuralFewer than 500 people per square mile614 minutes80 percent

Urban and suburban rows are from NFPA's second draft report for Table 4.3.2; the rural row is as reproduced by Sonoma LAFCO. The standard also defines remote zones and special-risk areas; confirm every value against the edition your jurisdiction has adopted. Members arriving under automatic aid count toward the minimum where an agreement is in place.

NFPA 1710 vs 1720 at a glance

NFPA 1710NFPA 1720
Applies toSubstantially career departmentsSubstantially volunteer departments
Time measureSeparate turnout and travel benchmarksCombined response time by zone
Compliance level90 percent for each benchmark90 or 80 percent, by zone
StaffingCompany and full-alarm minimums by hazardMinimum members assembled on scene by zone
Covers EMSYesYes

Turnout time, EMS response and two-in, two-out

Turnout time, the interval from the alert to the start of travel, is the part of response time a department controls most directly. NFPA's fact sheet for the 2020 edition sets it at 60 seconds for EMS and 80 seconds for fire responses, measured at the 90th percentile. NFPA 1710 also addresses EMS response for departments that provide it, which is why turnout and travel are measured separately for EMS and fire calls.

Initial attack staffing is often confused with the two-in, two-out rule. That rule comes from OSHA's respiratory protection standard, 29 CFR 1910.134(g)(4), not from NFPA 1710. See the two-in, two-out rule.

How to measure compliance

  1. Capture every timestamp. Alarm received, unit notified, unit en route, unit on scene, and the time the required staff assembled. These come from CAD and the incident record.
  2. Clean the data. Exclude cancelled responses and non-emergency moves consistently, and document the rule.
  3. Report percentiles, not averages. Compliance is the share of incidents meeting the benchmark. An average can look good while one call in five is late.
  4. Break it down. By station, shift, unit, hour and demand zone, so the cause of misses is visible.
  5. Publish on a schedule. Councils and accreditation reviewers expect the same report, the same way, every period.

The same timestamps feed NERIS incident reports and the communications and fire department sections of an ISO PPC review, so one clean incident record serves all three.

Reporting with Elarchon

Elarchon produces NFPA 1710 reporting from the same incident record that feeds NERIS, with timestamps taken from the CAD connector and the field. Chiefs see turnout and travel performance by station and unit without exporting to a spreadsheet. See Fire and Rescue.

Questions

What is the difference between NFPA 1710 and 1720?

NFPA 1710 applies to substantially career fire departments and sets time-based objectives at the 90th percentile for turnout and travel. NFPA 1720 applies to substantially volunteer departments and sets staffing and response time objectives by demand zone (urban, suburban, rural, remote), each with its own percentage of compliance.

What are the NFPA 1710 response times?

In the 2020 edition summarized in NFPA's fact sheet: turnout of 60 seconds for EMS and 80 seconds for fire; travel of 240 seconds for the first-arriving engine; and 480 seconds of travel for the initial full alarm assignment to a low or medium hazard fire, each met at least 90 percent of the time.

Is NFPA 1710 a law?

No. NFPA standards are consensus standards. They become binding only where a state, local ordinance or labor agreement adopts them. Many jurisdictions use them as performance targets in standards of cover and council reporting.

Which standard applies to a combination department?

It depends on how the department is substantially staffed. Departments that are substantially career generally use NFPA 1710; those that are substantially volunteer use NFPA 1720. Many combination departments measure against both and document which applies to which station or shift.

Does NFPA 1710 apply to EMS?

Yes. NFPA 1710 covers fire suppression, emergency medical operations and special operations by career departments, including turnout and travel objectives for EMS responses.

How do you measure NFPA 1710 compliance?

From time-stamped incident data: the time the alarm is received, the time units are notified, the time units begin moving, and the time they arrive. Compliance is the percentage of incidents that meet each benchmark, reported at the 90th percentile rather than as an average.

What is the NFPA 1710 turnout time?

In the 2020 edition summarized in NFPA's fact sheet, 60 seconds for EMS responses and 80 seconds for fire and special operations responses, measured from the alert to the start of travel and met at least 90 percent of the time.

Is NFPA 1710 mandatory?

Not by itself. NFPA standards are voluntary consensus standards; they become enforceable only where a state or local government adopts them or a contract or agreement requires them. Many departments still use NFPA 1710 as the benchmark for planning, budgeting and accreditation.

Does NFPA 1710 include the two-in, two-out rule?

The two-in, two-out requirement for interior structural firefighting comes from OSHA's respiratory protection standard, 29 CFR 1910.134(g)(4). NFPA 1710 addresses initial attack staffing separately. See the two-in, two-out rule.

Sources

  1. NFPA 1710: standard development page National Fire Protection Association
  2. NFPA 1710 fact sheet National Fire Protection Association
  3. NFPA 1720: standard development page National Fire Protection Association
  4. NFPA 1720 second draft report (Table 4.3.2) National Fire Protection Association
  5. Fire response time measures DC Fire and EMS Department
  6. Response standards appendix (NFPA 1720 table) Sonoma LAFCO
  7. 29 CFR 1910.134: Respiratory protection eCFR

Request a briefing

See Elarchon configured for your jurisdiction.

Briefings are prepared around your departments, incident types and reporting obligations.

Request a briefing