The two-in/two-out rule is OSHA's requirement in 29 CFR 1910.134(g)(4) that during interior structural firefighting, at least two firefighters enter the IDLH atmosphere together and stay in visual or voice contact, at least two remain outside ready to rescue them, and everyone in the interior attack wears SCBA. One of the two outside may also be the incident commander, and the rule does not prevent emergency rescue before the full team assembles.
The text of the rule
Paragraph (g)(4) of OSHA's respiratory protection standard, "Procedures for interior structural firefighting", states that in interior structural fires, the employer shall ensure that:
- at least two employees enter the IDLH atmosphere and remain in visual or voice contact with one another at all times;
- at least two employees are located outside the IDLH atmosphere; and
- all employees engaged in interior structural firefighting use SCBAs.
Two notes follow in the standard. The first allows one of the two individuals outside to be assigned an additional role, such as incident commander or safety officer, so long as that person is able to perform assistance or rescue without jeopardizing the safety or health of any firefighter at the incident. The second states that nothing in the section is meant to preclude firefighters from performing emergency rescue before an entire team has assembled.
When it applies
- Interior structural firefighting in an IDLH atmosphere. OSHA's interpretations state the requirement takes effect when firefighters begin interior attack, and that incipient-stage firefighting is outside it.
- The incident commander decides whether the fire is an interior structural fire requiring the procedure.
- The outside members must be trained, equipped and prepared to enter to rescue the members inside, according to OSHA's enforcement directive CPL 02-00-158.
Who it covers
Federal OSHA covers private-sector employers and federal agencies, not state and local governments. Public-sector firefighters are covered where the state runs an OSHA-approved State Plan that includes state and local government employees; those plans must be at least as effective as federal OSHA. OSHA's small entity compliance guide notes that state and local government employees in states without an approved plan are not covered unless the requirements are adopted locally. Many departments adopt the rule in policy regardless, and it is also reflected in NFPA standards.
The list of State Plan states changes. Check OSHA's current State Plan list and your state's rules before relying on coverage.
What two-in/two-out does not require
OSHA's directive states the rule does not require fire departments to hire additional firefighters and does not require four-person companies or four people on an apparatus. It requires that four trained, equipped people be on scene before an interior attack into an IDLH atmosphere, rescue excepted. A department with three-person engines can meet it when a second unit arrives. Staffing per unit is a separate question, addressed by standards such as NFPA 1710; see NFPA 1710 vs 1720.
Documenting it on the fireground and after
When two-in/two-out is challenged, the questions are factual: who was on scene, when they arrived, who was assigned outside and when interior operations began. Good records show:
- unit and member arrival times;
- assignments, including the outside team and any dual role such as incident commander;
- the time interior operations began and ended;
- any rescue performed before the team was assembled, and why;
- members' respirator medical clearance and fit testing, which the same OSHA standard requires.
How Elarchon helps
In Elarchon, unit timestamps and personnel on each incident are part of the incident record, Scheduling & Staffing shows who was on duty and on which apparatus, and Credentials & Training and Health & Exposure hold qualifications and medical clearance for each member. See scheduling and staffing.
Questions
What is the two-in/two-out rule?
Under OSHA's respiratory protection standard, 29 CFR 1910.134(g)(4), during interior structural firefighting at least two employees enter the IDLH atmosphere and stay in visual or voice contact, at least two employees remain outside, and all employees engaged in interior structural firefighting use SCBAs.
Can the incident commander be one of the two outside?
Yes. OSHA's note to paragraph (g) allows one of the two outside to have another role, such as incident commander or safety officer, as long as that person can perform assistance or rescue without jeopardizing the safety of any firefighter at the incident.
Is there an exception for rescue?
Yes. The standard states that nothing in it is meant to preclude firefighters from performing emergency rescue activities before an entire team has assembled.
Does two-in/two-out apply to volunteer or municipal fire departments?
Federal OSHA does not cover state and local government employees. Public-sector firefighters are covered where the state operates an OSHA-approved State Plan that includes public employees; elsewhere the rule applies only if adopted locally. Private and federal fire departments are covered by federal OSHA.
Does two-in/two-out require four firefighters on an engine?
No. OSHA's enforcement directive states the rule does not require departments to hire additional firefighters or to staff four people on an apparatus; it requires four people on scene before an interior attack into an IDLH atmosphere, except for rescue. Staffing levels are addressed by standards such as NFPA 1710.
When does two-in/two-out start?
When firefighters begin interior structural firefighting in an IDLH atmosphere. OSHA interpretations state that incipient-stage firefighting falls outside the requirement.
Sources
- 29 CFR 1910.134 Respiratory protection eCFR
- Two-in/two-out procedure in firefighting/IDLH environments (interpretation, April 29, 1998) OSHA
- CPL 02-00-158: Inspection procedures for the Respiratory Protection Standard OSHA
- Small Entity Compliance Guide for the Respiratory Protection Standard OSHA
- NFPA 1710 National Fire Protection Association