Hydrant management software keeps every fire hydrant on a map with its status, flow test results and maintenance history. In Elarchon, the water utility and the fire department share one hydrant record, so an out-of-service hydrant reported by either is visible to both, and pre-incident plans show the current status of the hydrants that serve each building.
The two-department problem
In most jurisdictions the water utility owns, repairs and flushes hydrants, while the fire department inspects them, tests them and depends on them during a fire. When each keeps its own list, the lists drift. A hydrant taken out of service for a main repair may still appear available on the engine's map. A hydrant the fire department found damaged may wait weeks to reach the utility's work queue.
Elarchon's Hydrant Management app records flow tests, out-of-service tracking and maintenance history on the same platform record used by both departments. The water utility's water and wastewater apps and the fire department's fire and rescue apps see the same hydrant.
What a hydrant record holds
| Field | Purpose |
|---|---|
| Location and ID | Mapped position, hydrant number, main it is connected to |
| Make, model and outlets | Outlet sizes and threads, year installed |
| Status | In service, out of service, restricted, with reason and date |
| Flow tests | Static and residual pressures, observed flow, calculated available flow, date and crew |
| Classification and marking | Rated capacity class and color marking |
| Inspections and maintenance | Inspection findings, lubrication, painting, repairs, flushing |
| Work orders | Open and completed repairs, with labor and parts |
Hydrant flow testing records
NFPA 291 is the recommended practice for water flow testing and marking of hydrants. A flow test uses at least two hydrants: one flowing water and one measuring residual pressure. The record should capture both hydrants, the static pressure before flowing, the residual pressure while flowing, the observed flow from each outlet, and the calculated flow available at a reference residual pressure. Results feed fire protection system design, pre-incident planning and the department's water supply records.
- Plan the test. Select flow and test hydrants on the map and notify the water utility and affected customers.
- Record static pressure. At the test hydrant before flowing.
- Flow and record. Observed flow at the flow hydrant and residual pressure at the test hydrant.
- Calculate and classify. Available flow at the reference residual pressure, and the hydrant's capacity class.
- Update the map. The result is attached to the hydrant record and visible from preplans.
Out-of-service hydrants
The most important field on a hydrant record is whether it works today. In Elarchon, either department can mark a hydrant out of service with a reason. The status shows on the map used by responding crews and in the pre-incident plans for nearby buildings, and the repair can be issued as a Work Order to the utility crew. When the repair is complete, the hydrant returns to service on the same record.
Hydrants and ISO
ISO's Public Protection Classification program evaluates community fire protection on a scale from Class 1 to Class 10 using its Fire Suppression Rating Schedule, and water supply is part of that evaluation. Complete hydrant inspection, flow testing and maintenance records are evidence the department and the water utility can produce. See our ISO PPC guide.
Choosing hydrant management software: questions to ask
- Do the water utility and the fire department work from the same hydrant list?
- Can either department mark a hydrant out of service, and does the responding crews' map reflect it?
- Are flow test results stored with both the flow and test hydrants?
- Can repairs be issued and tracked as work orders with labor and parts?
- Can you report hydrants overdue for inspection or testing?
Related capabilities
- Water and wastewaterMains, meters, sampling and lift stations on one record.
- Pre-incident planningBuilding plans, hazards and hydrants on the map before the call.
- Utilities and public worksWork orders, GIS assets and outage management.
Questions
What is hydrant management software?
Software that keeps an inventory of fire hydrants on a map with each hydrant's status, flow test results, inspections and maintenance history. It lets the water utility schedule work and lets the fire department see which hydrants are in service before and during a call.
Who should own hydrant records, the fire department or the water utility?
Usually the water utility owns and maintains the hydrants, and the fire department inspects and uses them. The problem is that each often keeps its own list. In Elarchon both departments work on one hydrant record, so an out-of-service hydrant reported by either is seen by both.
What should hydrant flow testing records include?
The test date, the flow hydrant and the test (residual) hydrant, static and residual pressures, observed flow, the calculated available flow at a reference residual pressure, the crew and any observations. NFPA 291 is the recommended practice for water flow testing and marking of hydrants.
How are hydrants color-coded?
NFPA 291 recommends classifying hydrants by rated capacity and marking them, typically by bonnet and cap color, so firefighters can judge available flow at a glance. Check your jurisdiction's adopted practice; some water systems use their own scheme.
Do hydrant records affect ISO ratings?
Water supply is part of how ISO evaluates a community's fire protection through its Public Protection Classification program. Complete records of hydrant inspection, testing and maintenance make that evaluation easier to support.
What is the difference between a feed hydrant and an attack hydrant?
These are fireground terms. A feed or supply hydrant supplies water to an engine that pumps it onward; an attack hydrant is one the first engine connects to directly at the scene. Hydrant software helps crews identify which nearby hydrants are in service and what flow they can expect.
Sources
- NFPA 291: Recommended Practice for Water Flow Testing and Marking of Hydrants National Fire Protection Association
- Public Protection Classification (PPC) program ISO / Verisk
- Critical infrastructure sectors Cybersecurity and Infrastructure Security Agency