Pre-incident planning software stores the plans firefighters need before they arrive: building layout, access, fire protection systems, hazards, utility shutoffs and the nearest water supply. In Elarchon, preplans sit on the map beside hydrants, inspections and past incidents, and crews can open them on the way to the call, with or without a signal.
What pre-incident planning software should do
A pre-incident plan is a summary of what an incident commander needs to know about a building or site before committing crews. Paper binders and PDF folders hold that information, but they go out of date and are hard to reach on the apparatus. Pre-incident planning software solves three problems: keeping plans current, making them findable in seconds, and connecting them to the rest of the department's records.
In Elarchon, Pre-Incident Planning is one of the apps in the platform: building plans, hazards and hydrants on the map before the call. Because every app shares one record, a preplan is linked to the building's inspection history, the hydrants that serve it, and every incident at that address.
What a complete preplan includes
| Section | What to record |
|---|---|
| Site and occupancy | Address, occupancy type, hours, occupant load, owner and emergency contacts |
| Building | Construction type, stories, square footage, roof, basements and attics |
| Access | Approach routes, gates, key boxes, apparatus positioning, staging areas |
| Fire protection | Sprinkler and standpipe systems, fire department connections, alarm panel location, control valves |
| Water supply | Nearest hydrants and their status, flow test results, alternate water sources |
| Utilities | Gas, electric and water shutoffs, generators, solar arrays |
| Hazards | Hazardous materials and quantities, high-voltage areas, structural concerns |
| Life safety | Occupants who need assistance, sleeping areas, refuge areas |
| Diagrams and photos | Site plan, floor plans, photographs of entrances, panels and connections |
A pre-incident plan example
Consider a two-story mixed-use building with a restaurant on the ground floor and offices above. A usable plan would show the front and alley access, the key box on the alley door, the fire department connection on the east wall, the sprinkler riser room, the gas meter behind the kitchen, the two hydrants within reach and their last flow test, the kitchen hood suppression system, and the after-hours contact for the property manager. Each item is a field or a pin on the map, not a paragraph, so it can be read in a moving vehicle.
How Elarchon keeps preplans current
- Plans live on the map. Each preplan sits at the building's location, so the plan for the address on the call is easy to find.
- Inspections inform reviews. Findings recorded in Inspections & Prevention are on the same record as the preplan, so changes in occupancy, systems or hazards are visible to whoever maintains the plan.
- Hydrant status flows in. Out-of-service hydrants and flow test results from Hydrant Management appear on the preplan without re-entry.
- Incidents add history. Every incident at the address, recorded in the NERIS-shaped incident record, is visible from the preplan.
- Crews see it in the field. The Offline Field App keeps plans available with no signal and syncs when back in range. Calls arrive through the CAD Connector from your existing CAD.
Prioritizing which buildings to preplan
No department can preplan every structure at once. A common approach is to start with buildings that combine high life-safety risk, high fire load or unusual hazards: assembly occupancies, health care and residential care facilities, schools, industrial sites with hazardous materials, and large or complex structures. A community risk assessment provides the data for that ranking. See community risk reduction.
Standards and references
NFPA 1620 was the recommended practice for pre-incident planning. NFPA has consolidated it into NFPA 1660, which brings emergency management, continuity and pre-incident planning content into one document. Departments should check the current edition and any state or local adoption before writing policy around it.
Planning work also supports the department's evaluation under ISO's Public Protection Classification program, which grades communities from Class 1 to Class 10 using the Fire Suppression Rating Schedule. See our ISO PPC guide.
Choosing pre-incident planning software: questions to ask
- Can crews open a plan from the call itself, without searching?
- Do plans work with no signal inside a building?
- Are preplans linked to inspection findings and hydrant status, or maintained separately?
- Can diagrams, photos and floor plans be added from a phone in the field?
- Can you report which target occupancies have no plan, or a plan past its review date?
Related capabilities
- Pre-incident plan templateA field-ready template with every section a complete preplan needs.
- Fire inspectionsScheduled inspections, violations, re-checks and fees.
- Hydrant managementFlow tests, out-of-service tracking and maintenance history.
- Fire & RescueNERIS-native incident records and every fire department app.
Questions
What is pre-incident planning software?
Software that stores pre-incident plans (also called preplans) for target buildings and sites: floor plans, access points, utility shutoffs, fire protection systems, hazardous materials, water supply and contacts. Good software puts each plan on a map and makes it available to crews in the field, including when there is no signal.
What should a pre-incident plan include?
At minimum: address and occupancy, construction and size, access and staging, fire protection systems and their connections, utility shutoffs, nearby hydrants and water supply, hazardous materials, life-safety concerns such as occupants who need assistance, and emergency contacts. Photographs and a simple site diagram make the plan usable at night and under stress.
Which NFPA standard covers pre-incident planning?
Pre-incident planning was covered by NFPA 1620. NFPA has consolidated that content into NFPA 1660, which also covers emergency, continuity and crisis management. Check the NFPA 1660 page for the current edition.
How often should pre-incident plans be updated?
Most departments review a plan whenever the building is inspected, when occupancy or construction changes, and on a fixed cycle set by local policy. Linking preplans to inspection records is the simplest way to keep them current, because each inspection prompts a review.
Can crews see pre-incident plans offline?
Yes. Elarchon's Offline Field App works with no signal and syncs when back in range, so a preplan opened en route remains available inside a building with poor coverage.
Do pre-incident plans help with ISO ratings?
ISO's Public Protection Classification program evaluates a community's fire protection using its Fire Suppression Rating Schedule. Keeping complete, current records of the department's prevention and planning work makes that evaluation easier to support. Elarchon also produces ISO PPC reporting from the same record.
Sources
- NFPA 1660 standard development (incorporates former NFPA 1620) National Fire Protection Association
- Public Protection Classification (PPC) program ISO / Verisk
- NERIS U.S. Fire Administration