ELARCHON Request a briefing

Hazardous materials

EPCRA Tier II reporting and hazmat response

Facilities report their hazardous chemicals to the fire department every year. Elarchon puts that information where it is needed: on the preplan, on the call and in the exposure record.

Updated November 21, 2026 · Reviewed against 6 official and primary sources · Editorial standards

EPCRA Tier II reporting is the annual hazardous chemical inventory that covered facilities must submit by March 1 to their State Emergency Response Commission, Local Emergency Planning Committee and local fire department, under section 312 of the Emergency Planning and Community Right-to-Know Act. Elarchon helps fire departments put that information to work: on pre-incident plans and inspections, in front of crews on the call, and in exposure records afterwards.

How EPCRA Tier II reporting works

The Emergency Planning and Community Right-to-Know Act exists so that communities, and the responders who protect them, know which hazardous chemicals are stored nearby. Sections 311 and 312 require facilities to report the hazardous chemicals they hold at or above threshold quantities. The rules are in 40 CFR Part 370.

QuestionAnswerSource
Who files?The owner or operator of a facility required to prepare or have available safety data sheets for hazardous chemicals present at or above threshold levels.40 CFR 370
Who receives it?The State Emergency Response Commission (SERC), the Local Emergency Planning Committee (LEPC) and the fire department with jurisdiction.40 CFR 370.45
When?On or before March 1 each year, covering the preceding calendar year. EPA states the deadline is statutory and cannot be extended, even when March 1 falls on a weekend.EPA
Tier I or Tier II?Tier I is the federal minimum; Tier II must be provided within 30 days of a request from the SERC, LEPC or fire department. Many states require Tier II from all reporting facilities.40 CFR 370.45
Negative reports?No federal requirement to declare that a facility is not subject to reporting; some states require it.EPA

New hazard categories from the 2027 reporting year

EPA published a final rule on June 22, 2026 (91 FR 37022) conforming the EPCRA 311 and 312 hazard categories to OSHA's amended Hazard Communication Standard. According to EPA, the revised categories are used for the 2027 reporting period, so facilities report them on forms due March 1, 2028. Fire departments that map Tier II hazard categories into preplans should expect the change in that cycle.

What the fire department does with Tier II data

A fire department receives Tier II information so it can plan. The practical questions are the same every year:

Answering those questions from a stack of annual submissions is slow. Answering them on the way to a call is impossible unless the information is already on the preplan the crew opens.

Hazmat response software in Elarchon

Elarchon connects the facility information a department receives with the records it keeps before, during and after a hazmat response.

AppHazmat use
Pre-Incident PlanningBuilding plans, hazards and hydrants on the map before the call, including where hazardous materials are stored.
Inspections & PreventionScheduled inspections of reporting facilities, violations and re-checks.
Incident Records (NERIS)The hazmat incident itself, structured to NERIS from the first field.
Health & ExposureExposure logs, physicals and long-term health records for every responder on the call.
Inventory & SupplyDecontamination and response supplies used and restocked.
Credentials & TrainingHazmat certifications, expirations and training hours.
Cost Recovery & BillingBilling for response where local ordinance allows.

Exposure records that last

Exposure is the part of a hazmat call that outlasts it. A responder's exposure to a chemical may matter years later, for a health claim or a medical evaluation. Health & Exposure keeps exposure logs on the responder's long-term record, linked to the incident and the chemical involved, rather than in a file that is hard to find when it is needed.

Hazmat incidents and disaster cost

When a hazmat release is part of a declared disaster, the response is emergency work. Labor, equipment and materials recorded on the incident support FEMA Public Assistance documentation without a second record.

An annual Tier II routine for fire departments

  1. Before March 1. Confirm the list of facilities expected to report in your response area, and how your state delivers Tier II data to the fire department.
  2. After March 1. Compare this year's submissions with last year's: new facilities, new chemicals, changed quantities or locations.
  3. Update preplans. Put chemicals, locations, hazards and emergency contacts on the preplan crews open on the call.
  4. Schedule inspections. Prioritize facilities with new or increased hazards.
  5. Check readiness. Match training, equipment and mutual aid arrangements to what is stored in your area.
  6. Request Tier II where needed. If your state collects only Tier I, request Tier II from a facility; it must respond within 30 days.

Facilities file Tier II reports themselves through their state's process. Elarchon does not file on their behalf and does not interpret a facility's reporting obligations; EPA and state agencies do.

Questions

What is EPCRA Tier II reporting?

Under section 312 of the Emergency Planning and Community Right-to-Know Act (EPCRA), facilities that must keep safety data sheets for hazardous chemicals at or above threshold quantities submit an annual inventory of those chemicals to the State Emergency Response Commission, the Local Emergency Planning Committee and the local fire department. Tier II is the detailed form of that inventory.

When is the Tier II deadline?

March 1 of each year, covering the chemicals present during the preceding calendar year (40 CFR 370.45). EPA states that the deadline is statutory and cannot be extended, including when March 1 falls on a weekend.

Is Tier I or Tier II required?

Federally, the minimum is Tier I information, and a facility must submit Tier II information within 30 days of a request from the SERC, LEPC or fire department (40 CFR 370.45). Many states require Tier II from every reporting facility, so check your state's requirements.

What changed in Tier II hazard categories?

EPA published a final rule on June 22, 2026 (91 FR 37022) updating the EPCRA 311 and 312 hazard categories to match OSHA's 2024 Hazard Communication Standard. EPA states the new categories apply to the 2027 reporting period, with forms due March 1, 2028.

How do fire departments use Tier II data?

To plan for incidents at reporting facilities: which chemicals are present, in what quantities and where; what hazards they pose to crews; and what the department needs on hand to respond. The value depends on getting that data in front of crews before and during a call.

Does Elarchon file Tier II reports for facilities?

No. Facilities file their own Tier II reports with the state, LEPC and fire department. Elarchon helps the fire department use the information it receives, on preplans, inspections, calls and exposure records.

Sources

  1. Emergency Planning and Community Right-to-Know Act (EPCRA) U.S. Environmental Protection Agency
  2. 40 CFR 370.45: When must I submit the inventory information? eCFR
  3. 40 CFR Part 370: Hazardous chemical reporting eCFR
  4. What is the 312 deadline if March 1 falls on a weekend? U.S. Environmental Protection Agency
  5. Revisions to hazard categories and reporting guidance U.S. Environmental Protection Agency
  6. Tier II negative reporting U.S. Environmental Protection Agency

Request a briefing

See Elarchon configured for your jurisdiction.

Briefings are prepared around your departments, incident types and reporting obligations.

Request a briefing