FEMA Category B: emergency protective measures

Most of what fire, EMS, police and emergency management do in a declared disaster falls under Category B. It is also where documentation is hardest, because the work happens fastest.

Updated November 21, 2026 · Reviewed against 7 official and primary sources · Editorial standards

FEMA Category B covers emergency protective measures: work that eliminates or lessens immediate threats to life, public health or safety, or immediate threats of significant additional damage to improved property (44 CFR 206.225). It includes most disaster work by fire, EMS, law enforcement and emergency management, such as search and rescue, evacuation, emergency medical care, security, sandbagging and EOC operations.

Category B is the second of the two emergency work categories in FEMA Public Assistance, after debris removal (Category A). It is authorized by Stafford Act section 403 for major disasters (42 U.S.C. 5170b) and section 502 for emergency declarations (42 U.S.C. 5192).

The eligibility test

Under 44 CFR 206.225(a)(3), an emergency protective measure must:

FEMA may require certification by local, state or federal officials that the threat existed, with an evaluation of the threat and the work recommended to address it (206.225(a)(2)). Work must also be in the declared area, within the incident period, and the legal responsibility of the applicant.

Category B by department

DepartmentTypical Category B workRecords that support it
Fire and rescueSearch and rescue, swift-water rescue, fire suppression caused by the disaster, hazmat response, pre-positioning and stagingIncident reports, unit and personnel rosters, hours by person, apparatus hours
EMSEmergency medical care and transport beyond normal operations, medical sheltering support, patient evacuationPatient care reports (counts, not PHI, for the claim), unit hours, staffing
Law enforcementSecurity of the affected area, traffic control, evacuation enforcement, curfew patrolsAssignment logs, overtime by person, vehicle hours
Emergency managementEmergency operations center activation, warning and public information, sheltering coordination, donations managementEOC sign-in sheets, ICS 214 activity logs, activation dates
Public works and utilitiesSandbagging, temporary levees, emergency pumping, barricades, emergency repairs to keep critical facilities runningWork orders, crew hours, equipment hours, materials used

Other eligible measures named in the regulation include emergency access, emergency communications and emergency public transportation (44 CFR 206.225(b)–(d)).

Labor: what is eligible

Labor is usually the largest Category B cost. For an applicant's permanently employed staff doing emergency work, FEMA generally reimburses overtime rather than straight-time salaries (44 CFR 206.228(a)(2)). Extra hires and mutual aid have their own rules. Track every person's hours by day, by activity and by location, with pay rates and fringe benefits, from the first hour. See force account labor and equipment for what a timesheet must show.

Equipment and materials

Applicant-owned equipment is reimbursed for the time it is actually operated on eligible work, at FEMA, state, tribal or local rates. See FEMA equipment rates. Materials drawn from stock (sandbags, fuel, barricades, medical supplies) need issue records showing what was used, where and when.

Deadlines

Emergency work must be completed within six months of the declaration. The state may extend that by up to six months for extenuating circumstances, and FEMA can approve longer extensions (44 CFR 206.204(c)).

Documentation that survives review

  1. Tie every hour to a threat. Record what immediate threat the work addressed and where.
  2. Separate normal operations from disaster work. A routine call during the incident period is not automatically Category B. Mark disaster-related activity explicitly.
  3. Capture people, equipment and materials together. Each assignment should show who, which units, how long and what was used.
  4. Keep mutual aid paperwork. Requests, agreements, rosters and invoices from assisting agencies.
  5. Keep it for the retention period. At least three years from the final financial report under 2 CFR 200.334, longer if an audit or appeal is open.

How Elarchon helps

In Elarchon, incident records, unit hours, personnel time and materials are written once, during the work, on the same record used for NERIS and EMS reporting. During a declared event, that activity can be tagged to the disaster and to Category B so the emergency work summary is assembled from what crews already recorded. Elarchon is not affiliated with FEMA and does not determine eligibility or guarantee reimbursement.

Questions

What is FEMA Category B?

Category B is emergency protective measures: actions taken before, during and after a disaster to eliminate or lessen immediate threats to life, public health or safety, or immediate threats of significant additional damage to improved property (44 CFR 206.225).

What are examples of FEMA Category B work?

Search and rescue, emergency medical care, evacuation and sheltering support, security and traffic control in the affected area, sandbagging and temporary levees, emergency operations center costs, demolition of structures that pose an immediate threat, emergency communications and emergency public transportation.

Is regular-time pay eligible under Category B?

For an applicant's own permanent employees performing emergency work, FEMA generally reimburses overtime, not straight-time salaries. 44 CFR 206.228(a)(2) sets the rule, and the Public Assistance Program and Policy Guide explains the exceptions, such as extra hires. See force account labor and equipment.

What is the deadline for Category B work?

Emergency work must be completed within 6 months of the declaration, with up to 6 more months available from the state for extenuating circumstances (44 CFR 206.204).

Is mutual aid eligible under Category B?

Mutual aid used for eligible emergency work can be eligible when it was requested, is documented and the requesting applicant is legally responsible for the cost. See mutual aid.

Can Category B be funded before a declaration?

Costs for eligible emergency protective measures taken in anticipation of the event, within the declared incident period, can be eligible. The declaration's incident period sets the dates.

Sources

  1. 44 CFR 206.225: Emergency work eCFR
  2. 44 CFR 206.228: Allowable costs eCFR
  3. 44 CFR 206.204: Project performance eCFR
  4. 42 U.S.C. 5170b: Essential assistance (Stafford Act section 403) Legal Information Institute
  5. 42 U.S.C. 5192: Federal emergency assistance (Stafford Act section 502) Legal Information Institute
  6. Public Assistance Program and Policy Guide, Version 5.0 (amended) FEMA